• Phone

    0086-757-25528371

  • Address

    Zone A, No. 5, Fuxin Road, Fuan Ind. Zone, Yuyuan Village Committee, Leliu Street Office, Shunde Dist., Foshan, Guangdong, China (Mainland)

  • E-mail

    k@waimaotong.com

LatestProducts

                            7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

                            7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

                            7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

                            7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

                            7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space hea,Audsun,Electronics,Home Appliance,Water Heaters,Heat Pump Water Heaters
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Type:
Air Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Storage
Housing Material:
Galvanized steel sheet and sprayed baking paint
Use:
Outdoor
Certification:
CE
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
Audsun
Model Number:
ARG-03C
name:
EVI heat pump
field:
floor heating
Compressor:
Copeland* ZW
Heat exchanger:
Shell Heat Exchanger
Evaporator:
Hydrophilic Aluminium Fin
Optional Casing:
Stainless Steel SUS304
Supply Ability
Supply Ability:
1000 Unit/Units per Month
Packaging & Delivery
Packaging Details
EVI heat pump Standard Export Packing
Port
Shunde /Guangzhou /Shenzhen
Video Description

 

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

 

Product Description

 

Audsun Audsun Cold Climate Air Source Heat Pump Specification
Model ARG-03CARG-04CARG-05CARG-10C
PowerSupplyV/Ph/Hz220-240V/1PH/50HZ220-240V/1PH/50HZ380-415V/3PH/50HZ380-415V/3PH/50HZ
*Ambient Temp.(Dry Bulb/Wet Bulb):7℃/6℃ ,Water Temp.(In/Out):30℃/35℃ 
OutputKW7.8512.1616.4833
InputKW1.934.018
COPW/W4.14.124.114.12
**Ambient Temp.(Dry Bulb/Wet Bulb):2℃/1℃ ,Water Temp.(In/Out):30℃/35℃    
OutputKW69.312.6225.2
InputKW1.92.964.028.05
COPW/W3.143.153.143.13
***Ambient Temp.(Dry Bulb/Wet Bulb):-7℃/-8℃ ,Water Temp.(In/Out):30℃/35℃    
OutputKW4.579.5119
InputKW1.92.964.018.02
COPW/W2.32.372.362.37
****Ambient Temp.(Dry Bulb/Wet Bulb):-15℃/-16℃ ,Water Temp.(In/Out):30℃/35℃    
OutputKW3.45.37.2214.5
InputKW1.852.873.897.8
COPW/W1.861.851.831.86
****Ambient Temp.(Dry Bulb/Wet Bulb):35℃/24℃ ,Water Temp.(In/Out):12℃/7℃    
OutputKW4.96.95918
InputKW1.973.014.148.3
EERW/W2.172.272.172.17
Compressor N/ACopeland Scroll EVICopeland Scroll EVICopeland Scroll EVICopeland Scroll EVI
Compressor QTYpc1112
Fan MotorN/ASide BlowingSide BlowingSide BlowingSide Blowing
Fan Motor QTYpc1222
RefrigerantN/AR407CR407CR407CR407C
Max. Water Temp.60
Refrigerant Control Electric Expansion Valve
Defrosting 4-way valve reverse auto defrosting
Working Temp.Min. :-20/Max.: +43
Nozzles SizeInch1111.5
Water Flow Ratem3/h2.5~3.03.5~4.03.5~4.06.0~6.5
NoisedB(a)60656568
Unit Dimension:cm850×520×1231305×505×12451305×505×12451565×575×1710
N.W/G.W:Kgs100/120145/170145/170330/370

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

Company Information

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

 

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

 7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

Packaging & Shipping

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

Our Services

1-Professional and diligent Audsun Export Team members , familiar with the import&export documents preparation;

2- More than 10 years experience in Audsun solar Water Heater and heat pump industry, know well of different countries and regions' water quality;

3- Fast response on the technical questions ;

4- Manufacture heat pump main components ,secure the lead time and strict quality control;

 

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

 

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application

 

 

 

 

7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application7.8KW EVI Cold Climate heat pump, minus 25 degree system work for both hot water and floor/space heating application